Chapter 4: Menu reference
92
CDC4 Door Controller Installation and Programming Manual
Active on days
Select the days of the week that the door schedule will be On (active) during the
active period.
Start time
Enter the start time for the start action.
Action duration
The action duration is the period of time that the Start action should remain in
effect. When the action duration expires, the End action will be triggered.
Enter a number of seconds, minutes, hours, and days.
Start action
Select the start action from the following options:
• No action: Take no action
• Unlock: Unlock the door
• Lock: Lock the door
• Disable: Disable the door
• Enable: Enable the door
End action
If an Action duration is defined, select the end action from the options. The
options are the same as for the Start action field. See the “Start action” section
above.
Region/HSU Configuration tab
Up to 16 High Security User (HSU) configurations can be defined.
See “High
” on page 54 for more information.
Click Browse “...” button to open the HSU configuration form.
On the HSU configuration form, click Remove to remove the HSU configuration
data.
The following settings are available.
Region
Select a region for the selected HSU configuration.
See also “Regions” on page 54.
Low limit
The minimum number of users required in the selected region. When the number
of users in the region is below the programmed value, the output defined in
“Below Low limit Output BUS” on page 93 is active.
Summary of Contents for CDC4
Page 1: ...CDC4 Door Controller Installation and Programming Manual P N 466 5478 REV D ISS 29OCT19 ...
Page 86: ...Chapter 3 Programming 80 CDC4 Door Controller Installation and Programming Manual ...
Page 120: ...Chapter 4 Menu reference 114 CDC4 Door Controller Installation and Programming Manual ...
Page 136: ...130 CDC4 Door Controller Installation and Programming Manual ...