100
Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
If set to No, the input needs both states to toggle between set and unset (pulse
key switch).
4.1.n.6.16 Key set
16 Key set
>Off<
The Key set option defines the zone as a key switch for area set. The following
options are available:
• Off: the area set is not affected by the zone.
• Key part set: zone is a key switch for area part set.
• Key full set: zone is a key switch for area full set.
4.1.n.6.17 Key unset
17 Key unset
>No<
If the Key unset option is set to Yes, the zone is a key switch that unsets an area.
4.1.n.6.18 Technical full set
18 Tech full set
>No<
If the Technical full set option is set to No, the technical alarms in this zone are
disabled when the area is fully set.
4.1.n.6.19 Technical unset
19 Tech unset
>No<
If the Technical unset option is set to No, the technical alarms in this zone are
disabled when the area is unset.
4.1.n.6.20 Technical part set
20 Tech part set
>No<
If the Technical part set option is set to No, the technical alarms in this zone are
disabled when the area is partially set.
4.1.n.6.21 Keypad LCD
21 Keypad LCD
>No<
If the Keypad LCD option is set to Yes, when the zone activates, the zone name
is displayed on the keypad LCD on all keypads, related to the area.