194
Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
Type
Description
Available parameters
Chime area
Change a chime functionality status
in the area
1. Areas selection
2. Status change: Clear, Set, or Toggle
Chime keypad
Change a chime functionality status
on the keypad
1. Keypad selection
2. Status change: Clear, Set, or Toggle
Set without exit
Immediate set (without exit time) [1] 1. Areas selection
2. User code requirement
Fire reset
Reset fire detectors [1]
1. Areas selection
Show open zones Show open zones [1]
1. User code requirement
Active alarms
Show zones in alarm state [1]
1. User code requirement
Active faults
Show faulty zones [1]
1. User code requirement
Alarm memory
Show acknowledged alarms [1]
1. User code requirement
Alarms to ACK
Show unacknowledged alarms [1]
None
UG control
Change user group privileges
1. UG identifier
2 and further - user group privilege.
Choose a privilege, and then change
it.
See “3.2.n.5 User group options” on
page 91 for more details.
Keypad control
Change keypad options
1. Keypad identifier
2. State change: lock or unlock
Walk test
Run walk test [1]
1. Area selection
Output test
Test outputs [1][4]
1. Output selection.
4 outputs can be assigned.
These outputs are switched on
simultaneously for the longest time
period configu
red in “8.1.2.1
2. User code requirement.
Test pic to CS
Take a picture and send it to a
central station
1. Camera
2. Central station
Fire
Raise a fire alarm
None
Medical alarm
Raise a medical alarm
None
Show inhibited
Show inhibited or isolated zones,
keypads, and expanders.
None
GSM credit
Check GSM credit
None
[1] Depending on system settings, the function may require logging in of a user with the
appropriate privileges.
See “2.2.1.n.3.9 Quick set” on page 72 for more details.
[2] Set and part set function start time is the time when the warning timer is started. The warning
time must be taken into account. See
“5.n.4 Warning time” on page 114 for more details.
[3] The function is an entry to the appropriate user menu. See
Advisor Advanced Manager
Manual
for more details.
[4] The function requires logging in of the supervisor or the installer.
[5] The function requires logging in of the supervisor.