Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
61
1.2.9.1.m.n.1 Test time
1 Test time
> 10<
Set duration (in minutes) for battery test.
Allowed range is 2 to 254.
1.2.9.1.m.n.2 Batt.test freq
2 Batt.test freq
>Disabled<
Set automatic battery test frequency. The following values are available:
• Disabled
• Every working day
• Every Monday
• First Monday of month
• Everyday
1.2.9.1.m.n.3 Start time
3 Start time
>00:00<
Set the time of the day when the device runs an automatic battery test.
1.2.9.2 Man. Bat. test
1>Panel
3 Exp
The menu allows you to perform a manual test of the device battery.
1.2.9.2.m Select device type
1>Exp 1
2 Exp 2
Select the appropriate device group.
1.2.9.2.m.n Select device
1>Test time
2 Run/Stop test
Select the appropriate device.
1.2.9.2.m.n.1 Test time
1 Test time
> 10<
Set duration (in minutes) for battery test.
Allowed range is 1 to 254.