Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
219
Group
Event
#
Event description Notes
HA-ALARM
79
A hold-up alarm
Reset after unset
HB-ALARM
80
B hold-up alarm
Reset after unset
Keypad
OFFLINE
1
Keypad is offline
Active if a keypad is offline
RTE
2
RTE triggered
Keypad RTE input triggered
CODETAMPER
3
Code tamper
Active when a keypad is locked
for 2 minutes due to 3 wrong
PIN entries
TAMPER
4
Keypad tamper
Keypad tamper
DURESS
5
Duress code
Duress code entered on this
keypad
ACTIVE CARD
6
Badged card
A card is badged on this keypad,
active for 3 s
PIN
7
Valid PIN
Valid PIN entered on this
keypad, active for 3 s
DOORACC
8
Valid PIN or card
Valid PIN or card entered on this
keypad, active for 3 s
LOCKED
9
Keypad is locked
Code tamper. It restores after
the timeout has expired.
ISOLATED
10
Keypad is isolated
CHIME
11
Keypad chime
active
VALID CARD
12
Valid card
Valid card entered on this
keypad, active for 3 s
EXIT STARTED
13
Exit time started
Exit time started during set from
the selected keypad
ENTRY STOPPED
14
Entry time stopped Entry time stopped during unset
from the selected keypad
Expander OFFLINE
1
Expander is offline
Active if device is offline
MAINSFAULT
2
Mains fail
BATTFAULT
3
Battery fail
TAMPER
4
Expander tamper
Device tamper
FUSEFAULT
5
Fuse fault
SIRENFAULT
6
Siren fault
RCVFAULT
7
Receiver fault
Wireless expander receiver fault
ISOLATED
8
Expander isolated
Panel
MAINSFAULT
1
Mains fault
Panel mains fault detected
BATTFAULT
2
Battery fault
TAMPER
3
Panel tamper
FUSEFAULT
4
Panel fuse fault
SIRENFAULT
5
Panel siren fault
LF
6
Line fault
A line fault is detected
LFPSTN
7
PSTN line fault
PSTN line fault detected