Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
Group
Event
#
Event description Notes
EXITFAULT
60
Exit fault
Alarm detected during exit state
before changing to part or full
set state
RTS
61
Ready To Set
Active when all configured RTS
conditions are valid
SETOK
62
Area set OK
Active for 2 s when area set
successfully
SETFAULT
63
Area set failed
Active during 30 s after
unsuccessful area setting
UNSETOK
64
Area unset OK
Active for 2 sec when area has
been unset
ALARMACK
65
Alarms to ACK
Alarms present waiting for
acknowledge
FIRERESET
66
Fire reset
For FIRE zone, event active for
10 s after fire alarm
acknowledge (also inhibits fire
zone for 15 s). Also active for 10
s during fire zone walk test
WALK
67
Walk test
User/Installer Walk test is active
WALKZNACTV
68
Walk test zone
active
Zone in walk test is activated
A-ALARM
69
A-Alarm
A-alarm active (unconfirmed
alarm), reset after unset or
expiration of AB timer and no B-
alarm.
B-ALARM
70
B-Alarm
B-alarm active (confirmed
alarm). Reset after unset
ISIREN
71
Internal siren
Internal siren. Activated on
alarm during the internal siren
time. Activation may be delayed
by Siren delay time.
Can be retriggered by next
alarm.
ESIREN
72
External siren
External siren. Activated on
alarm during the external siren
time. Activation may be delayed
by Siren delay time.
This flag can not be retriggered.
STROBE
73
Strobe output
Strobe output. Activated by
alarm during Set. Deactivated
after unset.
BUZZER
74
Buzzer output
Buzzer output flag
AMRESET
75
AM reset
Activated during set procedure
to reset AM detectors
PARTSET2
76
Area part set 2
Area is in part set 2 state.
AS WARNING
77
Autoset warning
Area in warning state prior to
autoset
AUTO SET
78
Autoset
Autoset procedure is in progress