![background image](http://html.mh-extra.com/html/interlogix/advisor-advanced-ats-000a-series/advisor-advanced-ats-000a-series_installation-and-programming-manual_2076744037.webp)
Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
27
Standard onboard outputs
S1, S2
High current electronic output, rating: 1 A at 13.8 V
S3, S4, S5 [1]
Low current electronic output, rating: 50 mA at 13.8 V
[1] Maximum cable length for low current output connection may not exceed 30 m. For longer
distances, use relay output expansion (for example, ATS624 four-relay expander).
Environmental
Operating temperature
0 to +40°C
Tested temperature according
EN 50131
−10 to +55°C
Humidity
95% noncondensing
IP protection grade
IP31
Colour
Beige
Dimensions
See “List of panel variants” on page vi
EN 50131 grade and class
ATSx000A(-IP): Grade 2, Class II
Safety class
Class I
Enclosure type
Enclosure (meets UL94V-0)
Overvoltage category
Category II
Maximum altitude, or minimum air
pressure
2000 m above mean sea level
Fuses
Battery
2 A, resettable
12 V aux
1 A, resettable
System databus
1 A, resettable
Siren 1, high current output S1
1 A, resettable
Siren 2, high current output S2
1 A, resettable
Mains, mains fuse:
ATS1000A(-IP)
315 mA, fast 20x5
ATS2000A(-IP)
630 mA, fast 20x5
Note:
Mains fuse is part of the mains terminal block.
WARNING:
Before removing the mains fuse, mains power must be disconnected
(see