Server System SR2600UR/SR2625UR Service Guide
119
10. If necessary, install the I/O expansion module. For instructions, see
I/O Expansion Module” on page 96
11. If necessary, install the Intel
®
RMM3. For instructions, see
12. Connect all additional cables to the server board as necessary.
13. Install the processor air duct. For instructions, see
.
14. Install the PCI riser assembly. For instructions, see
.
Replacing the Backup Battery
The lithium battery on the server board powers the RTC for up to 10 years in the absence
of power. When the battery starts to weaken, it loses voltage, and the server settings stored
in CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your
customer service representative or dealer for a list of approved devices.
Warning:
Danger of explosion if battery is incorrectly replaced. Replace only with the same or
equivalent type recommended by the equipment manufacturer. Discard used batteries
according to manufacturer's instructions.
Advarsel:
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med
batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.
Advarsel:
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av
apparatfabrikanten. Brukt batteri returneres apparatleverandøren.
Varning:
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ
som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens
instruktion.
Varoitus:
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan
laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden
mukaisesti.
To replace the backup battery, follow these steps:
1. If installed, remove the PCI riser assembly. For instructions, see
PCI Riser Assembly” on page 50
.
2. If installed, remove the processor air duct. For instructions, see
Processor Air Duct” on page 56
3. Locate the battery on the server board (see
4. Insert the tip of a small flat bladed screwdriver, or an equivalent, under the tab in
the plastic retainer. Gently push down on the screwdriver to lift the battery.
Summary of Contents for SR2600UR - Server System - 0 MB RAM
Page 4: ...iv Intel Server System SR2600UR SR2625UR Service Guide...
Page 8: ...viii Intel Server System SR2600UR SR2625UR Service Guide...
Page 18: ...xviii Intel Server System SR2600UR SR2625UR Service Guide...
Page 20: ...xx Intel Server System SR2600UR SR2625UR Service Guide...
Page 26: ...6 Intel Server System SR2600UR SR2625UR Service Guide...
Page 158: ...138 Intel Server System SR2600UR SR2625UR Service Guide...
Page 166: ...146 Intel Server System SR2600UR SR2625UR Service Guide...
Page 170: ...150 Intel Server System SR2600UR SR2625UR Service Guide...
Page 176: ...156 Intel Server System SR2600UR SR2625UR Service Guide...
Page 186: ...166 Intel Server System SR2600UR SR2625UR Service Guide...
Page 210: ...190 Intel Server System SR2600UR SR2625UR Service Guide...
Page 234: ...214 Intel Server System SR2600UR SR2625UR Service Guide...