Server System SR2600UR/SR2625UR Service Guide
Restoring the BIOS Defaults
If you need to restore the BIOS default settings, the BIOS Default jumper will need to be
used.
1. Power down the system; do not disconnect the AC power.
2. Open the server system. For instructions on removing the system cover, see
“Removing the System Cover” on page 48
3. Locate the BIOS Default jumper block at board position J1E7.
4. Move the jumper from the normal operation position (covering pins 1 and 2) to the
Set Default position (covering pins 2 and 3).
Figure 133. BIOS Default Jumper
5. Wait five seconds.
6. Return the BIOS Default jumper to the normal position (covering pins 1 and 2).
7. Close the server system.
8. Power up the system.
AF003113
J1E7
BIOS Default
2
3
Normal
Set
Default
Summary of Contents for SR2600UR - Server System - 0 MB RAM
Page 4: ...iv Intel Server System SR2600UR SR2625UR Service Guide...
Page 8: ...viii Intel Server System SR2600UR SR2625UR Service Guide...
Page 18: ...xviii Intel Server System SR2600UR SR2625UR Service Guide...
Page 20: ...xx Intel Server System SR2600UR SR2625UR Service Guide...
Page 26: ...6 Intel Server System SR2600UR SR2625UR Service Guide...
Page 158: ...138 Intel Server System SR2600UR SR2625UR Service Guide...
Page 166: ...146 Intel Server System SR2600UR SR2625UR Service Guide...
Page 170: ...150 Intel Server System SR2600UR SR2625UR Service Guide...
Page 176: ...156 Intel Server System SR2600UR SR2625UR Service Guide...
Page 186: ...166 Intel Server System SR2600UR SR2625UR Service Guide...
Page 210: ...190 Intel Server System SR2600UR SR2625UR Service Guide...
Page 234: ...214 Intel Server System SR2600UR SR2625UR Service Guide...