![Intel SR2600UR - Server System - 0 MB RAM Service Manual Download Page 58](http://html1.mh-extra.com/html/intel/sr2600ur-server-system-0-mb-ram/sr2600ur-server-system-0-mb-ram_service-manual_2072151058.webp)
38
Server System SR2600UR/SR2625UR Service Guide
For RAID 0, 1, and 10, enclosure management is provided over the bridge board.
If RAID 5 is desired, the optional Intel
®
RAID Activation Key AXXRAKSW5 can be
installed. To enable RAID 5, this activation key is placed on the SATA Key connector that
is located at the left side of the server board. For information on installing the Intel
®
RAID Activation Key AXXRAKSW5 accessory to enable RAID 5, see
RAID Activation Key and the RAID Mini-DIMM” on page 111
For information on configuring RAID, see the
Intel
®
RAID Software User’s Guide
that is
included on the
Intel
®
Server Deployment Toolkit 3.0 CD
.
Advanced Management Options
Intel® Remote Management Module 3
The Intel
®
Remote Management Module 3 plugs into a dedicated connector on the server
board and provides additional server management functionality to the server board.
This module provides a dedicated web server for viewing server information and remote
control of the system. It also provides Remote KVM Redirection and USB Media
Redirection allowing USB devices attached to the remote system to be used on the
managed server.
For instructions on installing the Intel
®
Remote Management Module 3, see
Remote Management Module 3” on page 98
Rack Mount Options
Your Intel
®
Server System SR2600UR/SR2625UR can be mounted into a rack. Intel
provides the following three options to mount this server system into a rack:
•
Fixed mount relay rack / cabinet mount kit: This kit can be configured to mount the
system into either a 2-post rack or 4-post cabinet.
•
Tool-less sliding rail kit: This kit is used to mount the system into a standard (19
inches by upto 30 inches deep) EIA-310D compatible server cabinet. An optional
cable management arm can be used with this kit.
•
Basic three-quarter extension sliding rail kit: This kit is used to mount the system
into a standard (19 inches by upto 30 inches deep) EIA-310D compatible server
cabinet.
When installing the system into a rack, Intel recommends you install systems from the
bottom of the rack to the top. In other words, install the first system in the rack into the
bottom position of the rack, the second system in the second position from the bottom, and
so on.
For instructions on installing your chassis into a rack, see
. These instructions are also included in the rail kit.
Summary of Contents for SR2600UR - Server System - 0 MB RAM
Page 4: ...iv Intel Server System SR2600UR SR2625UR Service Guide...
Page 8: ...viii Intel Server System SR2600UR SR2625UR Service Guide...
Page 18: ...xviii Intel Server System SR2600UR SR2625UR Service Guide...
Page 20: ...xx Intel Server System SR2600UR SR2625UR Service Guide...
Page 26: ...6 Intel Server System SR2600UR SR2625UR Service Guide...
Page 158: ...138 Intel Server System SR2600UR SR2625UR Service Guide...
Page 166: ...146 Intel Server System SR2600UR SR2625UR Service Guide...
Page 170: ...150 Intel Server System SR2600UR SR2625UR Service Guide...
Page 176: ...156 Intel Server System SR2600UR SR2625UR Service Guide...
Page 186: ...166 Intel Server System SR2600UR SR2625UR Service Guide...
Page 210: ...190 Intel Server System SR2600UR SR2625UR Service Guide...
Page 234: ...214 Intel Server System SR2600UR SR2625UR Service Guide...