48
Intel
®
Server System SR1600UR Service Guide
DIMM Blank Installation Requirements
In order to maintain adequate thermal levels, you MUST install DIMM blanks in the
appropriate DIMM slots as described below:
•
If you have only one processor installed, all CPU 1 DIMM slots must either have a
DIMM or DIMM blank installed. You may either leave the CPU 2 DIMM slots
empty or store extra blanks in the blue DIMM slots.
•
If you have both processors installed, all blue DIMM slots in CPU 1 and CPU 2
must either have a DIMM or DIMM blank installed. You may store extra DIMM
blanks in any of the unused CPU 1 DIMM slots.
For additional information regarding memory requirements and options, refer to the
Intel
®
Server System SR1600UR Technical Product Specification
.
For a web link to the list of
tested DIMMs, see
“Additional Information and Software” on page 3
.
Installing DIMMs
To install DIMMs, follow these steps:
1. Remove the PCI riser assembly. For instructions, see
“Removing the PCI Riser
Assembly” on page 41
.
2. Remove the processor air duct. For instructions, see
“Removing the Processor Air
Duct” on page 46
.
3. Locate the DIMM sockets (see
Figure 34
).
Summary of Contents for SR1600UR - Server System - 0 MB RAM
Page 4: ...iv Intel Server System SR1600UR Service Guide...
Page 6: ...vi Intel Server System SR1600UR Service Guide...
Page 8: ...viii Intel Server System SR1600UR Service Guide...
Page 14: ...xiv Intel Server System SR1600UR Service Guide...
Page 18: ...xviii Intel Server System SR1600UR Service Guide...
Page 122: ...104 Intel Server System SR1600UR Service Guide...
Page 126: ...108 Intel Server System SR1600UR Service Guide...
Page 132: ...114 Intel Server System SR1600UR Service Guide...
Page 142: ...124 Intel Server System SR1600UR Service Guide...
Page 166: ...148 Intel Server System SR1600UR Service Guide...
Page 190: ...172 Intel Server System SR1600UR Service Guide...