90
Intel
®
Server System SR1600UR Service Guide
3. Slide the control panel out through the front of the server system (see letter “D” in
Figure 79
).
Figure 79. Removing the Standard Control Panel Module
4. Connect the USB and data cables to the local control panel (see letters “A” and “B”
in
Figure 80
).
5. Feed the control panel cables through the chassis opening (see letter “C” in
Figure 80
).
6. Slide the replacement control panel into the server system (see letter “D” in
Figure 80
) until it clicks into place.
7. Connect the two cables to the USB and front panel connectors on the backplane
(see letters “E” and “F” in
Figure 80
).
Figure 80. Installing Control Panel Module into the Server System
D
C
Locking
Lever
Backplane
A
B
AF002915
Local
Control Panel
Backplane
E
A
B
C
F
AF002950
D