Server System SR1600UR Service Guide
59
2. Slide the hard drive carrier out of the server system (see letter “B” in
Figure 45
).
Figure 45. Removing Fixed Mount Drive Carrier from the Server System
3. Remove the four screws securing the plastic retention device to the drive carrier
(see
Figure 46
). Store the plastic retention device for future use. Also, save the
screws; you need them to install the hard drive into the carrier.
Figure 46. Removing the Drive Blank from the Fixed Hard Drive Carrier
4. Remove the hard drive from its wrapper and place it on an antistatic surface.
5. Set any jumpers and/or switches on the drive according to the drive manufacturer's
instructions.
6. With the drive circuit-side down, position the connector end of the drive so that it is
facing the rear of the drive carrier.
7. Align the holes in the hard disk drive to the holes in the drive carrier and attach it to
the carrier with the screws that were attached to the plastic retention device (see
Figure 47
).
Carrier Latch
AF003017
A
B
AF002380
Summary of Contents for SR1600UR - Server System - 0 MB RAM
Page 4: ...iv Intel Server System SR1600UR Service Guide...
Page 6: ...vi Intel Server System SR1600UR Service Guide...
Page 8: ...viii Intel Server System SR1600UR Service Guide...
Page 14: ...xiv Intel Server System SR1600UR Service Guide...
Page 18: ...xviii Intel Server System SR1600UR Service Guide...
Page 122: ...104 Intel Server System SR1600UR Service Guide...
Page 126: ...108 Intel Server System SR1600UR Service Guide...
Page 132: ...114 Intel Server System SR1600UR Service Guide...
Page 142: ...124 Intel Server System SR1600UR Service Guide...
Page 166: ...148 Intel Server System SR1600UR Service Guide...
Page 190: ...172 Intel Server System SR1600UR Service Guide...