![Intel SBCEGBESW1 Manual Download Page 223](http://html1.mh-extra.com/html/intel/sbcegbesw1/sbcegbesw1_manual_2073124223.webp)
RMON Commands
Intel® Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide
207
•
type
— Specifies the method used for sampling the selected variable and calculating
the value to be compared against the thresholds. Possible values are
absolute
and
delta
.
•
If the method is
absolute
, the value of the selected variable is compared directly with
the thresholds at the end of the sampling interval. If the method is
delta
, the selected
variable value of the last sample is subtracted from the current value, and the
difference is compared with the thresholds.
•
direction
— Specifies the alarm that may be sent when this entry is first set to valid.
Possible values are
rising
,
rising-falling
and
falling
.
•
If the first sample (after this entry becomes valid) is greater than or equal to
rthreshold
and
direction
is equal to
rising
or
rising-falling
, a single rising alarm is generated. If
the first sample (after this entry becomes valid) is less than or equal to
fthreshold
and
direction
is equal to
falling
or
rising-falling
, a single falling alarm is generated.
•
name
— Specifies the name of the person who configured this alarm. If unspecified,
the name is an empty string.
Default Configuration
The type is
absolute
.
The startup direction is
rising-falling
.
Command Mode
Global Configuration mode
User Guidelines
There are no user guidelines for this command.
Example
The following example configures the following alarm conditions:
•
Alarm index — 1000
•
Variable
identifier — Intel
•
Sample interval — 360000 seconds
•
Rising threshold — 1000000
•
Falling threshold — 1000000
•
Rising threshold event index — 10
•
Falling threshold event index — 20
Console(config)#
rmon alarm
1000 Intel 360000 1000000 1000000 10 20