Intel® Modular Server System MFSYS25 User Guide
21
2. Press the retention lever latch button to release the retention lever (see letter “A” in
the following figure). Rotate the lever out and away from the module bay (see letter
“B”) and pull the storage controller straight out the back of the chassis (see letter
“C”).
Warning:
You must replace the storage controller with a filler panel or another
storage controller within two minutes.
Figure 12. Removing a Storage Controller
3. Replace the storage controller with a filler panel or another storage controller within
two minutes.
AF002430
A
C
B