12
Intel® Modular Server System MFSYS25 User Guide
Caution: When lifting the system, DO NOT lift by the power supply or fan module handles.
3. All compute modules, hard drives, power supply modules, I/O modules, and cooling
modules should be removed before placing the Intel
®
Modular Server System
MFSYS25 in a rack.
4. The Intel
®
Modular Server System MFSYS25 can only be installed in a rack cabinet
with perforated front and rear doors.
5. Plan device installation starting with the bottom of the rack cabinet.
6. Do not leave unused space within the rack cabinet opening; blank filler panels must be
used to fill gaps and prevent recirculation of warm air.
7. Ensure the power outlets in the rack are sufficient in quantity and load capacity to
support all devices intended to be installed in the rack.
Installing Temporary Handles on System
Temporary handles are provided with your Intel
®
Modular Server System. These handles
are intended to aid in the movement of the system during removal from packaging and
during initial configuration and installation. However, the profile of the handles is such
that it prevents their use when the system is installed in a standard 19-inch rack.
1. Handles are to be mounted to the top edges of both the front and rear of the system.
2. Install front and rear handles by inserting handle tabs into chassis slots and tightening
captive screws.
Figure 6. Installing Temporary Handles
1
I/O
2
ID
1
2
1
I/O
2
ID
1
2
AF002418
8
9
10
11
12
13
14
1
2
3
4
5
6
7
1
2
3
4
5
6
Summary of Contents for MFSYS25 - AXXPSU 1000W Power Supply Module
Page 12: ...xii Intel Modular Server System MFSYS25 User Guide ...
Page 22: ...10 Intel Modular Server System MFSYS25 User Guide ...
Page 110: ...98 Intel Modular Server System MFSYS25 User Guide ...
Page 120: ...108 Intel Modular Server System MFSYS25 User Guide ...
Page 124: ...112 Intel Modular Server System MFSYS25 User Guide ...
Page 136: ...124 Intel Modular Server System MFSYS25 User Guide ...