Functions
MoRoS GPRS 2.1 PRO
In order to enable incoming connections in "Connection on request" mode
as well, check the checkbox "Accept incoming connection" and enter the
port, on which the serial Ethernet gateway reacts on incoming connec-
tions, into the entry field "TCP port" (it is possible to allow incoming and
outgoing connections at the same time). If an incoming or outgoing con-
nection is active in this case, the other is not available until the active
connection is closed.
In order to specify that the connection is only accepted, if an UDP authen-
tication of an INSYS VCom has taken place, check in the "VCom authenti-
cation" section the checkbox "incoming". An existing connection will be
terminated by a VCom authentication during the existing connection. This
setting is ignored if IPT is used.
In order to specify that an ATD dialling command triggers an outgoing
connection, select in the "Outgoing connection" section the radio button
"triggered by dialling command ATD". Then, the serial interface will be
operated in AT command mode and a connection must be initiated by an
ATD command. The Serial Ethernet Gateway expects the dialling com-
mand ATD via the serial interface with the destination as IP address or
domain name, followed by the TCP port (e.g.: ATD192.168.1.1:1234 or
ATD"name.company.com":1234. When using IPT, only the IPT number is
specified here (e.g.: "ATD12345").
In order to specify that a character on the serial interface triggers an out-
going connection, select in the "Outgoing connection" section the radio
button "triggered by serial character". Then, a connection will be estab-
lished as soon as a WAN connection is established. A destination must be
specified in this operation mode. Enter the IP address or the domain name
of the target into the "IP address or domain name" field as well as the port
into the "Port" field. Alternatively, enter for an IPT connection the IPT
number into the "IPT dial number" field. A secondary target can be en-
tered optionally, to which a connection will be established if the primary
target is not available. If the connection set-up fails, a new connection set-
up cannot be performed before 5 minutes have expired.
In order to specify a set-up of an outgoing connection by an active WAN
connection, select in the "Outgoing connection" section the radio button
"triggered by active WAN connection". Then, a connection will be estab-
lished as soon as a WAN connection is established. A destination must be
specified in this operation mode. Enter the IP address or the domain name
of the target into the "IP address or domain name" field as well as the port
into the "Port" field. Alternatively, enter for an IPT connection the IPT
number into the "IPT dial number" field. A secondary target can be en-
tered optionally, to which a connection will be established if the primary
target is not available.
In order to establish a connection in leased line mode, it is also necessary,
to enter the IP address or the domain name of the target as well as the
port or the IPT dial number. A secondary destination can be entered op-
tionally.