Functions
MoRoS GPRS 2.1 PRO
12.8.3
Switch Outputs
The MoRoS GPRS 2.1 PRO has digital outputs, whose status can be queried and
changed via the web interface.
The outputs can also be operated daily at a certain time. Moreover, it is possible to
operate the outputs by establishing a PPP connection, an OpenVPN tunnel, a PPTP
tunnel, or a serial Ethernet connection.
Configuration with the web interface
In order to query the status of the outputs, change to the menu "In-
/Outputs" and the page "Outputs". The status of the outputs is displayed
in the section "Manual switching of outputs" by the radio buttons next to
the text "Output 1/2".
In order to change the state of the outputs, select in the menu "In-
/Outputs" on the page "Outputs" in the section "Manual switching of out-
puts" for the respective output "Idle condition" or "Operated condition"
using the radio buttons and click "OK".
In order to switch an output to operated condition daily at a certain time,
check in the section "Switching times Output 1/2" the checkbox "Swit-
ches to operated condition at" and enter into the following field the time
for operating the respective output.
In order to switch an output to idle condition daily at a certain time, check
in the section "Switching times Output 1/2" the checkbox "Switches to
idle condition at" and enter into the following field the time for releasing
the respective output.
In order to configure output 1 for an operation with the presence of a PPP
connection, select under "Function of output 1" the option "Switches to
operated condition if a PPP connection is established".
In order to configure output 2 for an operation with the presence of an
OpenVPN tunnel, select under "Function of output 2" the option "Swit-
ches to operated condition if an OpenVPN tunnel is established".
In order to configure output 2 for an operation with the presence of an
PPTP tunnel, select under "Function of output 2" the option "Switches to
operated condition if an PPTP tunnel is established".
In order to configure output 2 for an operation with the presence of an IP-
sec tunnel, select under "Function of output 2" the option "Switches to
operated condition if an IPsec tunnel is established".
In order to configure output 2 for an operation with the presence of a se-
rial Ethernet connection, select under "Function of output 2" the option
"Switches to operated condition if a serial Ethernet connection is estab-
lished".
Save your settings by clicking "OK".