Nix Product Manual |
Connectors Guide
INGENIA | 01/22/2019
40
6
GND
Common (internally connected to drive GND)
7
TX+
RS485 transmit data + (should be connected to master RX+)
8
TX-
RS485 transmit data - (should be connected to master RX-)
Notes
• Polarization hole on PCB indicates pin 1 and ensures correct mating connector position.
• See
for further information about RS485 wiring.
• Nix connectors include locking latches that provide audible click during mating and ensure assembly
robustness
Ribbon cable mating
Description
TE Micro-Match Male-on-Wire 1.27 mm pitch 8 position
Part number
Distributor codes
Farnell
Cable
Part number
Distributor codes
Farnell
Multi-core crimped cable mating
Description
TE Micro-Match housing connector 1.27 mm pitch 8 position
Part number
Distributor codes
Cable
Use 0.2 ~ 0.5 mm² (20 ~24 AWG) flexible cable.