Next figure shows the circuit model of the digital encoder inputs.
Digital encoders with single ended 24 V outputs
Nix Servo Drive can also interface single ended digital encoders with output voltages higher than 5 V, for instance
24 V PLC level encoder. With the use of series connected limiting resistors, Nix is able to read encoder counts
correctly while the inputs are correctly protected.
It is recommended to use a 4.7 kΩ 1/4 W resistor in series with the ENC_X- (inverting) input and leave the ENC_X+
floating.