Nix Product Manual |
Connectors Guide
INGENIA | 01/22/2019
44
R5
GND
Ground connection
R6
GND
Ground connection
R7
TX+
RS485 transmit data + (should be connected to master RX+)
R8
TX-
RS485 transmit data - (should be connected to master RX-)
C1
CAN_GND
CAN ground (isolated from Nix power GND)
C2
CAN_L
CAN bus line dominant low
C3
CAN_H
CAN bus line dominant high
C4
CAN_GND
CAN ground (isolated from Nix power GND)
F1
+5V_OUT
+5V 200mA max output (shared with I/O and absolute encoder connectors)
F2
GND
Ground connection
F3
ENC_A+/SIN+
Single ended digital encoder: A input
Differential digital encoder: A+ input
Sin-Cos encoder: Sin+ input
F4
ENC_A-/SIN-
Differential Encoder: A- input
Sin-Cos encoder: Sin- input
F5
ENC_B+/COS+
Single ended digital encoder: B input
Differential digital encoder: B+ input
Sin-Cos encoder: Cos+ input
F6
ENC_B-/COS-
Differential Encoder: B- input
Sin-Cos encoder: Cos- input
F7
ENC_Z+/REF+
Single ended digital encoder: Index input
Differential digital encoder: Index+ input
Sin-Cos encoder: Re input
F8
ENC_Z-/REF-
Differential Encoder: Index- input
Sin-Cos encoder: Reference- input
F9
GND
Ground connection
F10
HALL_1
Hall sensor input 1 (analog and digital)
F11
HALL_2
Hall sensor input 2 (analog and digital)