140
Chapter
6
Fault Messages
045 FIRMWARE ERROR*
SEE USERS MANUAL
No
Application software
tried to perform an illegal
printer function or
damaged memory is
detected on the
controller board.
Contact your InfoPrint
service representative.
046 EC STOPPED AT
STATE
<state>
No
Controller self–test and
initialization sequence
was halted at <state>,
where <state> is one of
10 numerically coded
messages.
Contact your InfoPrint
service representative.
051 HAMMER SHORT*
SEE USERS MANUAL
No
Hammer driver circuits
on the controller board
shorted to ground.
Contact your InfoPrint
service representative.
052 MECH DRIVER HOT
SEE USERS MANUAL
No
Mechanism driver
temperature is elevated
beyond normal
threshold.
Contact your InfoPrint
service representative.
053 48 VOLTS FAILED*
RECYCLE POWER
No
The power supply is not
generating a proper 48
volts or the CMX board
is not properly detecting
a 48 volt output.
Contact your InfoPrint
service representative.
054 HAMMER COIL
SHORT*
SEE USERS MANUAL
No
Hammer coil shorted to
ground.
Contact your InfoPrint
service representative.
055 MECH. DRIVER LINK
FAILURE
SEE USERS MANUAL
No
Link failure between the
the controller board and
mechanism driver board.
Contact your InfoPrint
service representative.
056 HAMMER COIL CHECK
SEE USERS MANUAL
No
Hammer coil open.
Contact your InfoPrint
service representative.
057 CLOSE PLATEN
Yes
Platen lever is raised to
the open position.
Lower the platen lever.
Table 8: Fault Messages
Fault Message
Operator
Correctable?
Explanation
Solution
Summary of Contents for 6500 DBCS
Page 2: ......
Page 6: ......
Page 10: ...Table of Contents...
Page 20: ...20 Chapter 1 Printer Overview...
Page 28: ...28 Chapter 2 Printer Component Locations...
Page 114: ...114 Chapter 4 Printer Information Menu...
Page 128: ...128 Chapter 5 IEEE 1284 Parallel Interface...
Page 184: ...184 Appendix A Printing Rates...
Page 188: ...188 Appendix B Printing Speed...
Page 212: ...212 Communication Statements...
Page 228: ...228...
Page 229: ......