72
Chapter
4
Ethernet Parameters Menu
Job Control
The job control mode has three options:
•
Standard
(default). The NIC waits for the printer to finish receiving the
current job before sending another job. The status line shows “done”
when the job is completely received by the NIC. This is the default.
•
Enhanced
. The NIC waits for the printer to finish receiving the current job
before sending another job. The status line shows “done” when the job is
fully printed.
•
Off
. No job synchonization between the NIC and the printer.
Ethernet Hotport
Gives the printer the ability to handle multiple data streams simultaneously. It
allows the printer to service hosts attached to the Serial and Ethernet ports as
if they were the only interface connected.
•
Timeout
. This is the value used by the printer to time out from the current
port and check the other ports for data to print. When the printer has not
received data from the host after a certain period of time, it needs to
timeout to service the other ports.
•
10 Sec
(the default)
•
10 sec - 60 sec
.
Summary of Contents for 6500 DBCS
Page 2: ......
Page 6: ......
Page 10: ...Table of Contents...
Page 20: ...20 Chapter 1 Printer Overview...
Page 28: ...28 Chapter 2 Printer Component Locations...
Page 114: ...114 Chapter 4 Printer Information Menu...
Page 128: ...128 Chapter 5 IEEE 1284 Parallel Interface...
Page 184: ...184 Appendix A Printing Rates...
Page 188: ...188 Appendix B Printing Speed...
Page 212: ...212 Communication Statements...
Page 228: ...228...
Page 229: ......