Fault Correction Procedure
141
058 SHUTTLE JAM
SEE USERS MANUAL
No
No shuttle movement or
the shuttle is moving at
the wrong speed.
Make sure the ribbon is
not twisted and the platen
lever is set correctly. If
the fault reoccurs,
contact your InfoPrint
service representative.
059 CANCEL PRINT
ACTIVE
N/A
Non–error status
message.
No action required.
060 PRINTER HOT
SEE USERS MANUAL
No
Printer temperature is
elevated beyond normal
threshold.
Contact your InfoPrint
service representative.
062 EXHAUST FAN CHECK
SEE USERS MANUAL
Yes
Sensors cannot detect
current in fan circuit.
Power off the printer.
Check for obstruction of
vents and fan airway;
remove any obstructions.
Check for items beneath
the printer blocking
cabinet vents. Power
back on the printer. If this
message reoccurs,
contact your InfoPrint
service representative.
NOTE:
This message
should not appear on a
Pedestal model. If this
message does appear,
contact your InfoPrint
Service Representative.
065 HAMMER FAN CHECK*
SEE USERS MANUAL
Yes
Sensors cannot detect
current in fan circuit.
Power off the printer.
Check for obstruction of
vents and fan airway;
remove any obstructions.
Check for items beneath
the printer blocking
cabinet vents. Power
back on the printer. If this
message reoccurs,
contact your InfoPrint
service representative.
069 DATA CLEARED
N/A
Appears when data is
cleared out of printer
after
Cancel
key has
been pressed.
No action required.
Table 8: Fault Messages
Fault Message
Operator
Correctable?
Explanation
Solution
Fault Messages
Summary of Contents for 6500 DBCS
Page 2: ......
Page 6: ......
Page 10: ...Table of Contents...
Page 20: ...20 Chapter 1 Printer Overview...
Page 28: ...28 Chapter 2 Printer Component Locations...
Page 114: ...114 Chapter 4 Printer Information Menu...
Page 128: ...128 Chapter 5 IEEE 1284 Parallel Interface...
Page 184: ...184 Appendix A Printing Rates...
Page 188: ...188 Appendix B Printing Speed...
Page 212: ...212 Communication Statements...
Page 228: ...228...
Page 229: ......