24
5.3.5.3 Set Monitor Contacts
The menu SET MONITOR CONTACTS is used to configure MON
CONTACT TABLE, so that the alarm video triggered by this alarm
will be switched automatically to the associated monitor.
ACN 001 002 003 004
0001 N N N N
0002 N N N N
0003 N N N N
0004 N N N N
0005 N N N N
0006 N N N N
0007 N N N N
0008 N N N N
A
MON/CONTACT TABLE - -
MONITORS
PREVIOUS MENU
PREVIOUS MENU
SET ALARM
1 SET MONITOR ARM TYPES
2 SET ALARM CONTACTS
3 SET MONITOR CONTACTS
4 SET ALARM TITLE
The menu has multiple screen pages, each permitting setup
operations for 8 alarm contacts and 4 monitors. Scroll the menu
page down to setup more alarm contacts and page forward for more
monitors (see Section 5.2).
Item
Function
A
MON CONTACT
TABLE
Select one of the 5 Monitor/Contact Tables to program.
Note
The menu provides 5 Monitor/Contact Tables (0-4), each defining a set of different
Monitor/Contact associations.
Table 0, displayed as
MON/CONTACT TABLE - -
, is the default table that indicates the
Monitor/Contact arming status currently active in the system.
ONLY Event Timers (see
Section 5.3.4
) can activate Tables 1-4.
To select a Table to program,
1)
Move the cursor to the entry;
2)
Enter the desired table number (0-4), and press the ACK key to select.
Monitor/Relay Contact options
Y = yes (to allow alarmed videos triggered by the alarm contact to be automatically switched to the monitor);
N = no (to disable the monitor from automatically responding to the alarm contact).
Example
To allow alarmed videos triggered by Alarm Contact 9 to be automatically switched to Monitor 5,
1)
Press the ON key in the AUXILIARY section to display entries for Monitor 5;
2)
Press the OPEN key in the IRIS section to display entries for Alarm Contact 9;
3)
Move the cursor to the entry that indicates Monitor 5 and Alarm Contact 9;
4)
Use the ACK key to select "Y".
ACN 005 006 007 008
0009 Y N N N
5.3.5.4 Set Alarm Title
Through the menu SET ALARM TITLE, user can set titles for all
the alarm as per requirement. And the menu is shown below:
TITLE-
PREVIOUS MENU
ALARM-0001
PREVIOUS MENU
SET ALARM
1 SET MONITOR ARM TYPES
2 SET ALARM CONTACTS
3 SET MONITOR CONTACTS
4 SET ALARM TITLE
A
B
C
ABCDEFGHIJKLM
NOPQRSTUVWXYZ
a b c d e f g h I j k l m
n o p q r s t u v w x y z
0 1 2 3 4 5 6 7 8 9<>
: - . / ;
The above menu is used to define a title for every camera. A title
can contain at most 16 characters.
Note:
If no alarm title is set, a camera title will be displayed in case of an
alarm; if an alarm title is set, the alarm title will be displayed in
case of an alarm.
Item
Function
A
ALARM
Selects an alarm for title programming.
To select a desired alarm,
1)
Move the cursor to the entry;
2)
Enter the title number on the keypad;
3)
Press the ACK key to select the alarm.
Note
Two cursors exist in this menu screen: one indicating the current active field, and the other
indicating the alphanumeric characters to be selected. The NEXT key is used to move the
field-positioning cursor, and the joystick is used to move the cursor within the selectable letters,
numbers and symbols.