23
Item
Function
F
CN
Connect Next (see the following examples for details).
Options
N
= no (no Connect Next function is desired).
Y
= yes (to call the camera in the next CAM entry simultaneously to the next contiguous
monitor).
ACN CAM DWL PRE AUX CN
0001 0001 05 01 1ON Y
0002 0002 00 01 0- N
The sample entries shown above indicate that when Alarm Contact 1 (ACN 0001) is alarmed,
Camera 1 (CAM 0001) will be automatically displayed on the monitor associated with Alarm
Contact 1 (see
Section 5.3.5.3
), and Camera 2 (CAM 0002) will be simultaneously displayed on
the next contiguous monitor.
Note:
The dwell time of CAM 0002 is defined as "00" since it is controlled by the previous entry,
CAM 0001.
The monitor arming types can be BSI, BSA, BSM, BHI, BHA, BHM when CN is set to ‘Y’
S
= salvo (to call up a system salvo).
Note:
At this point, the associated CAM entry indicates the salvo number.
ACN CAM DWL PRE AUX CN
0003 0001 10 00 0- S
The sample entries shown above indicate that when Alarm Contact 3 (ACN 0003) is alarmed,
System Salvo 1 (CAM 0001) will be automatically called up. The monitor associated with Alarm
Contact 1 (see
Section 5.3.5.3
) will become the first monitor for the called salvo.
Note:
The monitor arming types can be BSI, BSA, BSM, BHI, BHA, BHM when CN is set to ‘S’.
W
= wired group (to activate all the ACN entries in a contiguous "wired group").
Note:
To define a "wired group", the last CN entry of the group must be set to "N" or "S" while all
the previous CN entries are set as "W".
ACN CAM DWL PRE AUX CN
0005 0005 02 01 1-ON W
0006 0006 02 01 0- W
0007 0007 02 01 0- N
The sample entries shown above have defined a "wired group" of three ACNs. If any alarm
contact in the group is alarmed, all the three associated cameras will be simultaneously called to a
contiguous group of monitors.
W< = wired group for group clear. Its only difference from W is the clearance method: clearing
the alarm on any of the alarmed monitors will clear all alarmed videos in the group, while a W
option requires manual clearance on each individual monitor.
Note:
1. The other three options, N<, Y<and S<, are factory reserved.
2. The alarms on the monitor must be cleared manually one by one when CN is set to
‘W<’and the arming type is SSM, SHM, BSM, BHM or DHM.
Item
Function
G
TE
Enable transmission. Serial number of transmission and the remote site number the transmission
goes to.
Option before “:”
Set the serial number for the alarm transmission. One local alarm can be transmitted to multiple
remote sites.
Option behind “:”
Y = Yes (Enable alarm transmitted to remote site).
If the option “Y” is selected here, enter the remote site number in the input field behind it.
N = No (Disable alarm transmitted to remote site. The system default is “N”).
Item
Function
H
RACN
The alarm contact number at a remote site triggered by a local alarm transmitted to the remote
site.
1)
Enter the alarm contact number of the remote site;
2)
Press ACK key to confirm.