![Incon OPTImizer 2 User Manual Download Page 73](http://html.mh-extra.com/html/incon/optimizer-2/optimizer-2_user-manual_2051173073.webp)
73
DSDP SF
6
Density & Temperature Sensor Specifications
Principal:
Oscillating Quartz Measurement
Density Measuring Range:
0 to 60 Grams per Liter (kg/m3) SF
6
Temperature Measuring Range:
-40 to +85 Degrees Celsius
Accuracy:
+/- 1% of measured value and +/- 1% of range
Repeatability:
+/-0.2% of measured value
Stability:
<+/-0.3% per year
Temperature Signal:
+/-1ºC @ ambient temperature, +/-3ºC at -40 to 85ºC
Output Signal:
Current pulses, frequency & pulse-width modulated
Supply Voltage:
10 to 20 Volts DC
Electrical Connections:
2-Wire (10 foot cable provided)
Operating Temperature:
-40 to +70 Degrees Celsius
Operating Pressure:
-1 to +20 Bar
Humidity:
98% Relative, Suitable for outdoor use
Vibration:
15 g (max 6 mm, 5-2000Hz) Shock 100g/6mS
Mounting Thread:
G ⅜" Male British Standard Parallel
Seal:
Neoprene O-ring (provided)
Weight:
Approx. 250 g without cable, 325g with cable