Basic System Management
81
Software Configuration Guide, Revision 1.03
System configuration has been changed.
Press 'yes' to store, 'no' to drop changes :
yes
10.9 Determining and Defining the active CLI Version
SmartWare allows having a number of CLI version installed together, whereas only one CLI version
is activated. There are commands available to determine the currently running CLI version and if
necessary switch to another CLI version. The idea of having several CLI version available on a
system is mostly to offer reduced or enhanced command sets to users.
Procedure
To determine the runinng CLI version and define another CLI version
Mode
Configure
Command
Purpose
Step 1
node
(cfg)#show version cli
Displays the currently running CLI version
Step 2
node
(cfg)#cli version
version.revision
Selects the active CLI version in the form
version.revision
Example: Defining the desired CLI Version
The following example shows how to determine the runinng CLI version and define CLI version 2.10
for your device, if you start from the configuration mode.
SN(cfg)#
show version cli
CLI version : 2.00
SN(cfg)#
cli version 2.10
10.10 Restarting The System
In case the SmartNode has to be restarted, the
reload
command must be used. The reload command
includes a two-step dialog, where the user is allowed to store any unsaved configuration data and
finally confirms the system restart.
Warning
Restarting the system interrupts running data transfers and all voice calls established via the
SmartNode that is to be restarted.
Procedure
To restart the currently running system.
Mode
Administrator execution
Command
Purpose
Step 1
node
#reload
Restarts the system
Example: Restarting The System
The following example shows how to restart the currently running system, if you start from the
administrator execution mode.
SN#
reload
Summary of Contents for SmartWare R2.00