Ethernet Port Configuration
105
the interface card fit for SmartNode 2000 series devices. All permanent on-board interfaces of a
SmartNode are described as being on slot 0. See the following table for more details.
Device Type
Interface Type
Slot
Port
Interface
0 ETH
0
Ethernet 0
1 ETH
1
0 BRI
0
SmartNode 1x00
ISDN 0
1 BRI
1
0 ETH
0/0
Ethernet 0
1 ETH
0/1
SmartNode 2x00
Serial 0
0
SERIAL
0/0
Table 11-1: Permanent built-in Interface Slot and Port Mapping for SmartNode 1x00 and 2x00
Series
14.4 Configuring Medium for an Ethernet Port
All Ethernet ports are configured by default to auto-sense both the port speed and the duplex mode.
This is the recommended configuration. Supported command options are:
•
10 for
10
Mbit/s
•
100
for 100 Mbit/s
•
auto
for auto-sense the port speed
Procedure
To configure the medium for the Ethernet port on
slot
and
port
Mode
Configure
Command
Purpose
Step 1
node
(cfg)#port ethernet
slot port
Enters Ethernet port configuration mode for the
interface on
slot
and
port
Step 2
node
(prt-eth)[
slot
/
port
]#medium
{10 | 100 | auto}
Configures interface on slot and port to medium
according to the selected option
Example: Configuring Medium for an Ethernet Port
The following example shows how to configure medium auto-sense for the Ethernet port on slot 0
and port 0 of a SmartNode 1000 or 2000 series device.
SN(cfg)#
port ethernet 0 0
SN(prt-eth)[0/0]#
medium auto
Software Configuration Guide, Revision 1.03
Summary of Contents for SmartWare R2.00
Page 2: ......