D
x
Telemetry System
Manual Vers. 2.7
47
/
92
Program:
The settings (“radio frequency” and “logical number”) are transmitted
to the SCT with the serial
number registered under “serial number”.
Then a reset of the transmitter module is required. To do this, please
disconnect the SCT power supply for at least 5 seconds.
IMPORTANT: Make sure that the SCT is sufficiently supplied while
programming and that no other SCT operates with the same
frequency.
Delete:
Delete this SCT from the configuration.
OK:
Exit menu.
IMPORTANT: In order to change settings permanently, you have to record your
current configuration with the
Save
button in the menu
Load/Save
4.2.3 Menu: Device
New Device
If you would like to use more SCTs you can easily add a new device with this menu entry. Up
to 4 SCTs of the same frequency can be operated via one RCI