- Messaging System Configuration
Deleting an AAA Server
AAA servers must be deleted in descending order. For example, if there are four servers in the order of
1, 2, 3, 4, the order in which the servers must be deleted is 4 3 2 1. Prior to attempting deletion of a
server whose order is not last, reorder the servers to change the desired deletion to the last number in
that order.
Use the following steps to remove an AAA server from the
User Authentication Servers
tab screen:
1.
At the
Servers
tab screen, select the highest numbered AAA
server from the
Order
column (see Figure 30, “User
Authentication - Servers,” on page 57)/
2.
Click
Delete
.
3.
At the
Delete Configuration
dialog (
), click
Yes
to
remove the specified AAA server.
Messaging System Configuration
The
Configuration -> Messaging System
tab allows you to configure parameters for the BNP to
integrate with external messaging systems, insert operator messages directly from the BNP GUI, or
configure the BNP to use external text or graphic files as overlay messages. You can also configure the
BNP to insert a graphics file (PNG) into one or more programs as a digital logo overlay. To configure
these features you must create specific Messaging or Logo Overlay zones under the
Messaging
System
tab, which are then associated to desired programs through the
Grooming -> Mapping
tab.
This section describes how to create both Messaging and Logo Overlay zones. See “Show Program List”
on page 89 for instructions on how to associate and enable programs to Messaging or Logo Overlay
zones.
About Messaging Zones
Use the
Messaging Zones
tab screen to view a snapshot of all messaging zones. This page also
provides a global parameter associated only with EAS messaging for system-wide configuration of
audio EAS override during DPI.
The number of messaging zones allowable is dependent on the following conditions at the
Configuration -> Global
tab screen (see Figure 18, “Global tab screen,” on page 37, and the EAS
Enable CAP description in
):
Table 30.
Global tab screen—Dependencies for Messaging Zones
Enable EAS CAP option
Description
unchecked
Up to ten messaging zone, of 400 characters each, can be configured
for the BNP.
checked
Up to two messaging zones can be configured for the BNP.
Per FCC requirement, up to 1800 characters are allowed on the EAS
messages. However, the BNP Element Manager displays only the first