Selenio
TM
BNP User Guide, Release 3.7.1
125
- Grooming - Mapping
Figure 73.
Creating Output TS (DVB) - ASI port
Select DVB to reveal
the DVB
configuration fields.
1.
At the
Create Output Transport Stream
dialog, enter information to define the DVB transport
stream on the ASI port:
-
Use guidelines from
to provide ASI port information at the upper portion.
-
Use guidelines from
to provide the DVB information.
2.
Click
OK
to save the settings, and to put the new TS at the
Outputs
panel of the
Mapping
screen,
beneath the selected ASI port.
Table 66.
DVB Output Transport Stream Configuration Parameters
Field
Description
Network ID
Input the Network ID of the current transport stream.
Modulation Mode
Use the pull-down menu to select the modulation mode used for the TS.
Choice between
SCTE 64 QAM
and
SCTE 256 QAM
.
Original Network ID
Input the Network ID from which this stream has originated.
NIT Source
Use the pull-down menu to select the source for the network information
table.
TDT/TOT Source
Use the pull-down menu to select the source for the time and date table or
the time offset table.
SDT Source
Source of the service description table for this transport stream. If you select
N/A then SDT is not generated for this output TS.
EIT Source
Source of the Event Information Tabled (EIT) for the programs in this
transport stream. If you select N/A then EIT will not be generated.