Unreferenced PID Pass Through
Use the steps in this section to create a ghost program with a data ES, and map the unreferenced PID
from a program input such as that shown in
.
Figure 114. Ghost Program With Unreferenced PID.
1.
Drag and drop the ghost program from the
Inputs panel
of the
Grooming -> Mapping
window
to the desired output transport stream to present the
Configure Mapping Window
.
Note the PID number of the component PID (in this case, 115). You will need this when you want to
create a referenced PID mapping.
2.
Be sure that the
Stay Unreferenced
box is checked, and click
OK
.
The ghost program and its data transport stream with PID of 0x73 (hex conversion from decimal)
appears on both the input and output (
) panels, which indicates that the stream has
been passed through.