![Illustra IFS03B1BNWIT Installation And Configuration Manual Download Page 82](http://html1.mh-extra.com/html/illustra/ifs03b1bnwit/ifs03b1bnwit_installation-and-configuration-manual_2044136082.webp)
Illustra Flex Series Installation and Configuration Guide
76
8200-1456-01 D0
5
Select the required configured fault action from the
Action
drop down menu.
- End -
Procedure 85 Enable/Disable an Alarm
Step Action
1
Select
Alarm I/O
from the
Event and Actions
menu.
2
Select the
Enabled
check box to enable the corresponding alarm.
OR
Clear the
Enabled
check box to disable the corresponding alarm.
- End -
Enable or Disable Alarm Output
Alarm Output allows the alarm to activate a digital output as an action. For example, this digital
output could be linked to an electrical device, i.e. a security light or siren.
Procedure 86 Enable/Disable Alarm Output
Step Action
1
Select
Alarm I/O
from the
Event and Actions
menu.
2
Select the
Output
check box to enable alarm output.
OR
Clear the
Output
check box to disable alarm output.
- End -
Procedure 87 Clearing Alarm Output
Step Action
1
Select
Alarm I/O
from the
Event and Actions
menu.
2
Under
Alarm Output
, select the
Apply
button to Clear Active Output.
The Alarm Output is cleared.
- End -
Analytics
Analytics is a feature which detects and tracks objects in video. Analytics supported are Region of
Interest, Motion Detection, and Blur Detection.
Region of Interest (ROI)
A region of interest is a defined area of the camera view which considered to be higher priority than
areas of non-interest. For example, in secure environments, areas of potential activity could be a
specific door or window. They are specified by drawing a rectangular overlay on the video stream.
The overlay is highlighted in green and an OSD is displayed outlining the size % for the x and y axis.
Up to five regions of interest can be configured, all of which can be enabled / disabled.