Inclination sensor JN
39
14.13 Restore the factory setting (system command 0x82)
To reset the user-specific parameters of the inclination sensor to the factory setting
the IO-Link system command 0x82 "Factory Reset" (ISDU index 2 = 0x82) has to
be sent to the sensor.
With the system command "Factory Reset" all parameters are reset to the factory setting. This
process cannot be reversed.
15 Status LED
The LEDs integrated in the two connectors indicate the respective state of the
device.
LED colour
Flashing frequency
Description
Green (left connector)
Permanently on
The device is in the "Run "state
Fashing
IO-Link communication
Yellow (right connector)
Permanently on
Switching status OUT1 / OUT2
16 Maintenance, repair and disposal
The device is maintenance-free.
►Dispose of the device in accordance with the national environmental regulations.
17 Approvals/standards
The CE declaration of conformity and approvals can be found at:
www.ifm.com → Data sheet search → JN2200