Inclination sensor JN
10
Index Sub-
index
Type
Value
Content
Read /
Write
Length
byte
40
0
---
Process Data
Input
0x cccc bbbb aaaa
cccc
→
PDVal2 (INT16)
bbbb
→
PDVal1 (INT16)
aaaa
→
Bool/DevStatus (UINT16)
Bit
0
→
--SW 1
Bit
1
→
--SW 2
Bit
2
→
--
Bit
3
→
--
Bit
4
→
Measuring method
Bit
5
→
Self-test active
Bit
6
→
--
Bit
7
→
--
Bit
8
→
DeviceStatus LSB
Bit
9
→
DeviceStatus
Bit
10
→
DeviceStatus MSB
Bit
11
→
--
Bit
12
→
--
Bit
13
→
--
Bit
14
→
--
Bit
15
→
--
R
6
8 Basic system settings and diagnostics
The JN2200 inclination sensor can be used for inclination or vibration
measurement. All parameter values that are of importance to the selected
measuring method are nevertheless always accessible and are saved in the
internal memory. They are part of the IO-Link data storage.
If the measuring method "vibration" is set, all parameters for setting the inclination
measurement and all angle-dependent parameters for the switching and analogue
outputs keep their values.
Characteristic values of the sensors such as measuring cell temperature and
current heating power as well as the results of the last self-test can be read via
own ISDU indices.