Inclination sensor JN
20
Another status bit indicates if the process values are not informative due to a
running self-test (in addition to ISDU index 4113).
The device status is indicated at any time via a bit field (in addition to ISDU index
36).
Name
Data type
Bit
offset
Bit
length
Value range
Unit
Switching
output 1
Boolean
0
1
0 = inactive
1 = active
Switching
output 2
Boolean
1
1
0 = inactive
1 = active
Measuring
method
Boolean
4
1
0 = inclination
1 = vibration
Self-test active
Boolean
5
1
0 = self-test inactive
1 = self-test running
Device status
UINT
8
3
000 = device functions reliably
001 = maintenance successful
010 = device outside the
specification
011 = check function
100 = fault
Process value
1
Int
16
16
Angle X for inclination measurement
V
eff
for vibration measurement
1/100 °
1/10 mm/s
Process value
2
Int
32
16
Angle Y for inclination measurement
A
pp
for vibration measurement
1/100 °
1 mg (*)
(*) 1 mg = 1/1000 g, 1 g = 9.80665 m/s² standard acceleration
13 Parameter setting of the analogue outputs
There are two analogue outputs (right M12 connector) on the sensor to pass
on the measured process values (inclination angle or vibration) to a machine
controller (PLC).
1: L+
24 V DC (+Ub-A)
2: A2
analogue output 2
3: L-
ground (GND)
4: A1
analogue output 1
M12 connector (right)
The characteristics of the analogue output can be adapted to the respective
application via the following parameters.