Inclination sensor JN
6
5 Scale drawing
33,
2
4,
5
90
75
22
45
62
5,3
M12 x1
M12 x1
6 Electrical connection
The inclination sensors are fitted with two round 4-pole M12 connectors (class A)
in accordance with IEC 60947-5-2. The M12 connectors are mechanically A-coded
in accordance with IEC 61076-2-101.
1: L+
24 V DC (+Ub-D)
2: OUT2
switching output 2
3: L-
ground (GND)
4: OUT1
switching output 1 or IO-Link
M12 connector (left)
1: L+
24 V DC (+Ub-A)
2: A2
analogue output 2
3: L-
ground (GND)
4: A1
analogue output 1
M12 connector (right)
The ground connections of the two round M12 connectors are directly
connected to each other internally; the supply voltage connections are
decoupled from each other.