UK
Inclination sensor JN
41
Index
Sub-
index
Type
Value
Content
Read /
Write
4105
0
UINT8
Zero x/y/z axis
2
→
absolute
measurement
R
4106
0
UINT8
Measuring method
0
→
angle indication
R/W
4107
0
UINT8
Axis selection for
vibration measurement
7
→
all 3 axes (x/y/z)
R/W
4108
0
UINT8
FIR filter step vibration
5
→
bandpass
10...400 Hz
R/W
4109
0
UINT8
Measuring range vibration
2
→
± 8 g
R/W
Inclination measurement
SP1/rP1 and SP2/rP2 = 50 % of the respective VMR,
ASP1/AEP2 and ASP2/AEP2 = 100 % of the respective VMR
Vibration measurement
SP1 = 20 % VMR/ rP1 = 19 % VMR
SP2 = 40 % VMR/ rP2 = 39 % VMR
ASP1/AEP2 and ASP2/AEP2 = 100 % of the respective VMR.
*VMR = final value of the measuring range