UK
Inclination sensor JN
7
7 IO-Link interface
The inclination sensors have a standardised IO-Link interface V1.1 and an IO-Link
device description according to IEC 61131-9. All measured values and parameters
are accessible via "Indexed Service Data Unit" (ISDU).
The individual configuration can be saved in the internal permanent memory
(EEPROM).
In the context of this unit manual the operating principle of IO-Link is assumed to
be known. In this connection we refer to the latest documents "IO-Link System
Description", "IO-Link Interface and System Specification" and "IO Device
Description Specification" published by the IO-Link consortium
(http://www.io-link.com).
The following features characterise the IO-Link interface:
Communication
●
IO-Link revision V1.1
●
Bit rate 38,400 bits/s (COM2)
●
Minimum cycle time 5 ms
●
Parameters are checked for valid values (range check)
Supported are
●
SIO mode
●
Block parameter setting
●
Data storage
●
Device Access Locks
●
Device status and detailed device status
Manufacturer and device identification
Vendor ID 310 / 0x0136
Vendor Name ifm electronic gmbh
Vendor
Text
www.ifm.com
Device ID 416 / 0x0001A0
Product Name JN2200
Product
ID JN2200
Product Text 2-axis inclination Sensor