Device manual AS-i M4 Gateway Profibus DPV1 (AC1375, AC1376)
2012-02-23
Further functions for Profibus DPV1
Read fieldbus parameters
409
Digital outputs
Master 2 (A)
16
OK
102
ESC
Step 11:
AC1375: Menu screen number = 54 (without function)
> Display how many bytes in the fieldbus master were configured for
digital outputs in the fieldbus master of single or A slaves on AS-i
master 2.
►
Press [OK] to scroll to the next display.
OR:
►
[ESC] to return to the screen [Fieldbus Address].
Digital inputs
Master 1 (B)
16
OK
103
ESC
Step 12:
AC1375: Menu screen number = 55
> Display how many bytes in the fieldbus master were configured for
digital inputs in the fieldbus master of B slaves on AS-i master 1.
►
Press [OK] to scroll to the next display.
OR:
►
[ESC] to return to the screen [Fieldbus Address].
Digital outputs
Master 1 (B)
16
OK
104
ESC
Step 13:
AC1375: Menu screen number = 56
> Display how many bytes in the fieldbus master were configured for
digital outputs in the fieldbus master of B slaves on AS-i master 1.
►
Press [OK] to scroll to the next display.
OR:
►
[ESC] to return to the screen [Fieldbus Address].
Digital inputs
Master 2 (B)
16
OK
105
ESC
Step 14:
AC1375: Menu screen number = 57 (without function)
> Display how many bytes in the fieldbus master were configured for
digital inputs in the fieldbus master of B slaves on AS-i master 2.
►
Press [OK] to scroll to the next display.
OR:
►
[ESC] to return to the screen [Fieldbus Address].
Digital outputs
Master 2 (B)
16
OK
106
ESC
Step 15:
AC1375: Menu screen number = 58 (without function)
> Display how many bytes in the fieldbus master were configured for
digital outputs in the fieldbus master of B slaves on AS-i master 2.
►
Press [OK] to scroll to the next display.
OR:
►
[ESC] to return to the screen [Fieldbus Address].