ifm
Device manual AS-i M4 Gateway Profibus DPV1 (AC1375, AC1376)
2012-02-23
Function
Introduction AS-i data
23
Notes:
Single, A and B slaves use the same structure for profiles:
S-[IO code].[ID code].[XID2 code]
IO code
I/O configuration, first digit in the slave profile
ID code
ID code, second digit in the slave profile
XID1 code
extended ID code 1, can be changed by the user, no part of the slave profile
(for AS-i slave version < 2.0 = F
h
)
XID2 code
extended ID code 2, third digit in the slave profile (for AS-i slave version 2.0 = F
hex
)
Details
chapter Configuration data (CDI) of the slaves (slave profiles) (
→
page
)
strSlaveList– fields with slave lists
5336
Bit / slave address
Word
no.
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
15(A) 14(A) 13(A) 12(A) 11(A) 10(A) 9(A) 8(A) 7(A) 6(A) 5(A) 4(A) 3(A) 2(A) 1(A) 0
*)
1
31(A) 30(A) 29(A) 28(A) 27(A) 26(A) 25(A) 24(A) 23(A) 22(A) 21(A) 20(A) 19(A) 18(A) 17(A) 16(A)
2
15B 14B 13B 12B 11B 10B 9B 8B 7B 6B 5B 4B 3B 2B 1B res.
3
31B 30B 29B 28B 27B 26B 25B 24B 23B 22B 21B 20B 19B 18B 17B 16B
*) There is no slave 0 in the LAS and LPS lists, therefore the master sets the field to "0"!