Device manual AS-i M4 Gateway Profibus DPV1 (AC1375, AC1376)
2012-02-23
Set-up
Change slave parameter data
135
AS-i 1 Slave 7
Digital Output
Parameter value
OK
151
ESC
Step 9:
►
Select [Parameter value] with [OK].
Parameter value
AS-i 1 Slave 7
Current: 1111 [ 0Fh ]
Setup: 1111 [ 0Fh ]
SET
154
ESC
Step 10:
> Display of current and setup parameter values as binary value and
hex value.
►
Press [ ] / [ ] setup value to set parameter data.
Parameter value
AS-i 1 Slave 7
Current: 1111 [ 0Fh ]
Setup: 1001 [ 09h) ]
SET
154
ESC
Step 11:
►
Press [SET] to save new parameter data on the slave.
Keep the key [SET] pressed until the change has been made!
Parameter value
AS-i 1 Slave 7
Current: 1001 [ 09h) ]
Setup: 1001 [ 09h) ]
SET
154
ESC
Step 12:
(If the setup value of the parameter data for this slave is not permitted:
> Display error message: "Slave data invalid“.
►
Repeat steps 10...12 with corrected values.)
> Setup parameter data is copied to the current parameter data.
►
Return to the start screen with [ESC].
> That's
it!