SmartPLC SafeLine AC4S with fieldbus interfaces
264
>
SF_OUT_local_single
43091
Interface type:
Local I/O interface (output)
Library:
sf_logicalinterfaces.library
Symbol in CODESYS:
>
Description
43285
Logical device for a 1-channel safe actuator at the local I/O interface
SF_OUT_local_single detects the Boolean value at the process data signal (OUT_). The logical device
generates a safe Boolean signal and provides the value at the configured output channel of the local
I/O interface (OUT_Channel).
>
Parameter data
43051
Parameter
Data type
Description
Possible values
OUT_Channel
INT
Local output to which the
actuator is connected.
1
...
4
Local output OUT1
...
local output OUT4
DisableLogging
Reserved - settings have no influence on function of the logical device
Process data
43137
Parameter
Data type
Description
Possible values
OUT_
SAFEBOOL
Target status of the output / the
outputs
FALSE
SAFE OFF
TRUE