SmartPLC SafeLine AC4S with fieldbus interfaces
189
Output parameters
43077
Parameter
Data type
Description
Possible values
Chan_A
BOOL
Logical state of the safe signal
channel A
(= 1st code half-sequence)
FALSE
OFF
TRUE
ON
Chan_B
BOOL
Logical state of the safe signal
channel B
(= 2nd code half-sequence)
FALSE
OFF
TRUE
ON
Ready
BOOL
Status of the FB processing
(validity of the output signals)
FALSE
FB not completely processed or
deactivated; signals are invalid
TRUE
FB completely processed; signals are
valid
Error
BOOL
Error indication
FALSE
No error
TRUE
Logical device is in the locked error
state S_ERROR
DiagCode
WORD
Diagnostic code of the internal
states of the controlled logical
device
Scope of the diagnostic code depends on the
controlled logical device: Description of the
selected logical device (
→
Library
SF_LogicalInterfaces.library
(
→ S.