Summary of Contents for STHC-ISG02DB-WS433-CL-04

Page 1: ...USER GUIDE FOR ICONNECTOR 3G INTEGRATED WIRELESS CO ORDINATOR STHC ISG02DB WS433 CL 04 USER GUIDE FOR ICONNECTOR 3G STHC B ISG02DB 03 Smart IoT Gateway iConnector...

Page 2: ...diagnostics as well as remote monitoring and control via any IIoT platform It is able to con gure the parameters for all end nodes in the network By the Sub Ghz technology from Texas Instruments it is...

Page 3: ...mension H106 x W73x D42 mm excluded antenna Net weight 190 grams Box dimension W160 x D150 x H100 mm Gross weight 300g After the power supply will have 5 minutes to add nodes value enb_auto_add_sensor...

Page 4: ...the power the iConnector wait a few minute and try again Node id added in this way will be written to thesmallest node_id_n address which is 0 Set Rssi_threshold see RF MODE CONFIG in the Modbus Memma...

Page 5: ...displays disconnected to connected It means the WS433 CL 04 is being connected with computer Next we need to import the configuration file for WS433 CL 04 by importing the csv file Go to MENU FILE Im...

Page 6: ...LOS condition However the two modules still communicate each other but the distance will be reduced significantly Therefore to maximize the transmission distance please pay attention to the following...

Page 7: ...frequency data rate of iConnector and the node 3 Read modbus normal health values but read the data of the node all are 0 The modbus 4 command only supports FW 1 9 old FWs can t read command 4 Check...

Page 8: ...4143 2288 Mobile 012 376 7181 Fax 603 4143 3388 Distributor in Australia and New Zealand temploggerlogo png Templogger Pty Ltd Tel 1800 LOGGER Email contact templogger net Manufacturer logo jpg Dai Vi...

Page 9: ...Primary battery 3 6V suitable for applications where no grid power like Water pipeline water network In addition STHC B is also powered by external power supply 7 48VDC or Solar panel system STHC B ha...

Page 10: ...ng 9 digits Digital Sensor Input 1 x Digital sensor input for DULP sensor type Digital Ultra Low Power M12 connector IP67 Battery Supply 1 x D size battery holder 3 6VDC External Power Supply 7 48VDC...

Page 11: ...save energy If we supply external power through M12 connector iConnector will run realtime After reading the sensor value the raw data isX it can be scaled to any technical value by the following form...

Page 12: ...he formula R W 914 392 4 float I2C prm1_b The b constants after calculation according to the formula R W 918 396 4 float I2C prm1_hi_cut Cut the upper threshold of I2C e g If prm1_scaled_value prm1_hi...

Page 13: ...Step 1 Open the cover of the iConnector Step 2 Connect the Configuration Cable to the UART Port in iConnector...

Page 14: ...Step 3 Power the iConnector via M12 male connector on iConnector Step 4 Connect the USB port of the Configuration Cable to the Computer...

Page 15: ...PxD Unzip file and run file application iconnector_config Choose COM Port the Port which is USB cable plugged in Set the BaudRate 9600 Parity none Click Connect untill the Status displays disconnected...

Page 16: ...played in theValue column shows the corresponding data the configuration is completed iConnector 3G uses micro SIM and needs to be configured to use the data network 1 Open iConnector cover and instal...

Page 17: ...e g 200 ms I2C num_of_sample The number of ADC samples taken in a reading of sensor data the more samples the longer the sensor reading time For example 8 samples with each sample have a reading time...

Page 18: ...r value read from I2C When iConnector only works with D type battery 3G network will turn off only when the 3G data sending cycle is turned on to send data after sending it will turn off Not sending a...

Page 19: ...Install the sensor as shown below 6 2 IO Wiring Sensor installation...

Page 20: ...Step 1 Open the back cover of the sensor Step 2 Wiring to sensors...

Page 21: ...Step 3 Connect Sensor to Input 4 20mA port of iConnector via M12 connector...

Page 22: ...lerun daviteq com wl id lT9lfZuEQUQksWLhFgSoQrs28sEGY0Kt Connect 7 48VDC power supply to iConnector via M12 Male connector Use M12 female connection cable to connect to iConnector 6 3 Power Supply Bat...

Page 23: ...Steps for battery installation Step 1 Using Flat Tip Screwdrivers to open the cover Step 2 Carefully pull out the top plastic housing 6 3 2 Battery installation...

Page 24: ...Step 3 Insert the type D battery 3 6VDC please take note the poles of battery Step 4 Insert the top plastic housing and locking by Flat Tip Screwdrivers No Phenomena Reason Solutions 7 Troubleshooting...

Page 25: ...e sever No power supply The network information of the SIM card data is incorrect No SIM card inserted Check the power supply Check that the battery is empty or not installed correctly Check the sim c...