SmartPLC SafeLine AC4S with fieldbus interfaces
257
Parameter data
43047
Parameter
Data type
Description
Possible values
IN_Channel_A
INT
Local input to which sensor
channel A is connected.
1
...
8
Local input IN1
...
local input IN8
IN_Channel_B
INT
Local input to which sensor
channel B is connected.
1
...
8
Local input IN1
...
local input IN8
EnableIN_Test
BOOL
Evaluation of a test signal which
was created by a local output
FALSE
Test signal is ignored *
TRUE
Test signal is evaluated
DisableLogging
BOOL
Transmission of the event
messages to OSC of the device
FALSE
Following states of the state diagram
are transmitted to the OSC: *
S_ON
S_OFF
S_Test
S_Error
S_Init (HW-Error)
TRUE
Following states of the state diagram
are transmitted to the OSC:
S_Test
S_Error
S_Init (HW-Error)
EnableStartupTest
BOOL
Control execution of the start-up
test
FALSE
No start-up test *
TRUE
Start-up test is executed; slave waiting
for start-up sequence OFF
ON
SynchTime
WORD
Synchronisation time
0
250
...
500
...
60000
Infinite
250 milliseconds
...
500 milliseconds *
...
60000 milliseconds
StabilisingTime
WORD
Max. bounce time
250
...
10000
250 milliseconds *
...
10000 milliseconds
ToleranceTime
WORD
Tolerance time for switch-off
250
...
1000
250 milliseconds *
...
1000 milliseconds
* ...
Default value
Process data
43139
Parameter
Data type
Description
Possible values
S_IN_dep_filter_no_testreq SAFEBOOL
Safe process signal
FALSE
SAFE OFF
TRUE
Safe ON
>