   G    S    M         G  A  T  E

 

 BlueGate ISDN 

 

 

 

 

 

Installation and Programming Instruction Manual                           

v 6.5

 

 

Summary of Contents for BlueGate ISDN

Page 1: ...G S M G A T E BlueGate ISDN Installation and Programming Instruction Manual v 6 5 ...

Page 2: ...IP Limitation of outgoing calls in GSM network Limitation of incoming calls from GSM network Priority connection through either the 1st or the 2nd GSM module LCR Switchable automatic channels changing Smart Call back automatic incoming calls routing up CLIP Volume setting in both directions separately for each GSM module Setting own time rate by 1 second or only in case of establishing connection ...

Page 3: ...her connector output ISDN line is used as a standard ISDN line connection to the exchange In this way the user does not lose the former IDSN line After proper LCR setting the selected calls are routed in GSM networks the other calls pass further in the former ISDN line The incoming calls are merged from both directions in the ISDN output Optional modules The gate can be provided with some of the m...

Page 4: ...cards The compartments for SIM cards will open after pressing the yellow pushbutton Before inserting SIM cards try their condition switching on with or without PIN etc using any GSM telephone If you wish to use switching on with PIN you have to set this PIN when programming the gate The gate will not operate without this setting Connect aerials The green LEDs indicate GSM modules feeding during op...

Page 5: ...rates in the function of a public telephone network in this mode i e it is a substitution of its network terminals NT ISDN does not provide devices feeds for the connected terminals TE mode setting by an extra order ISDN operates as a digital telephone apparatus i e it is a substitution of ISDN extension line with S0 interface It is necessary to check whether the terminal resistors S0 of the bus 1...

Page 6: ...in parallel with permanently activated S0 e g an exchange line The other connector is used for standard communication line connection to the exchange Indicating LEDs will light up after activation of individual lines Indication of active synchronization line Indication of active communication line Synchronization line connector Communication line connector ...

Page 7: ...om this input can be connected to the former ISDN line an exchange line The other connector is used as a standard ISDN line connection to the exchange Indicating LEDs will light up after activation of individual lines Indication of active input line Indication of active output line Input ISDN line Output ISDN line ...

Page 8: ...ing other locations for the aerial with respect to a very short wave length even a replacement by a mere ten centimetres can help according to experience from practice When looking for a suitable position the signal quality is more important than its strength analogy with ghost images in case of TV aerials If you are not successful we recommend using a directional aerial for GSM that eliminates re...

Page 9: ... operation will start flashing in an interval of 2 seconds quick flashing of the red LED for about 3 seconds will indicate module logging in the GSM network upper panel The green GSM1 LED on the front panel is flashing The GSM2 module will also be started within 20 seconds in an identical way Operation of GSM1 2 modules green LED is flashing module logged in the network rest condition LED lit up p...

Page 10: ...gnal is too weak The device is operating however the call contains a humming sound Unsuitable positioning of the aerial with respect to any of the analogue telephone lines or an analogue telephone apparatus into which GSM transmission is induced identical as in case of a car radio It is necessary to test mutual position or totally relocate it The device is operating however an echo can be heard in...

Page 11: ... tested by an authorized service company The green LED indicating line activation after cable connection will not light up Check the cable and its connection The green LED indicating PBX line activation will not light up attempting connection Check the cable and its connection ...

Page 12: ...nstalled in your PC and click on the Continue button You can position the icon created in the desktop area of your computer Program start The program can be started in a usual way i e by double clicking on its icon Reading the current parameters setting from the gate To enable communication with the gate it is always necessary to enter an access password identical with the password set in the gate...

Page 13: ...will indicate the type of the transfer yellow for data send green for data receive If any error occurs during transfer or the access password does not work the program will react with an error message Do not forget to turn the appropriate com1 or com4 on Parameters reading from and saving in your PC The parameters read from the gate or the parameters set manually in the program can be processed us...

Page 14: ...fer is successful the code in the field Password will be rewritten with the new code from the New password field If this is not the case the New password field will be rewritten with the current code from the Password field Setting GSM module parameters Setting the properties of the modules 1 and 2 is identical it differs only on indices Priority of GSM modul 1 At 1 modul is one more button for di...

Page 15: ... permission of incoming calls Outgoing calls permission of outgoing calls If e g only the Incoming calls field will be marked and the Outgoing calls will not be marked calling from this channel out will be blocked the incoming calls will pass without limitation Call Progress Tones switching ON OFF tones signalling searching of called part in GSM net Redirection to GSM2 In case of marking the Re ro...

Page 16: ...ns up to 8 digit number of the first direction from as in the case mentioned above and the last digit of the last direction is stored in the second column i e the last digit of to see Fig A group may be created only within the range of one order of the last position i e from 0 to 9 By proper filling in the tables of both modules one module e g T Mobile code the other module Orange code it is possi...

Page 17: ... incoming to the telephone number of the first channel will be connected to the direct dialling code 11 incoming calls to the number of the other channel e g to the direct dialling code 12 If a number of digits in the direct dialling code are being set the number will be higher than zero max 4 Caution the number should correspond with the number of digits of the direct dialling code of the exchang...

Page 18: ...pecial numbers If the rec field has been checked then message for channel 1 is recorded after dialling number 1 The same way message for modul 2 iis recorded after dialling number 2 The messages recorded from the phone can be 10 seconds for each channel The recording is finished by hanging up the phone 2 By recording from computer After connection of the convertor into gateway serial port RS 232 a...

Page 19: ...way Erase CLIP The gate supports transfer of CLIP from the GSM network in ISDN i e to a telephone connected to an extension if the device allows it Here it is advantageous to use the parameter for deleting the initial digits from CLIP e g deleting 42 in order not to confuse LCR exchanges when calling back to the displayed number AOC E Setting of taxation type Usually it is charging during the call...

Page 20: ...r refused are stored It stores PBX extension which made the call called number When called part calling back then the call is automatically routed to extension which made the call When connection was succsesfull data are erased from memory In the gateway memory can be stored up 500 records status when click on status button then is open the window where are mentioned all parametres about GSM modul...

Page 21: ...ou can use all services of GSM network without any restriction Mobile Network Code Mobile Country Code Mobile Area Code Network number provider where is GSM modul registrated logged Cell ID BTS number where is modul registrated Information mentioned in the window you can print out or after saving send to your Gateway supplier Remote configuration module The gate can be additionally provided with a...

Page 22: ...off inimodem ATE0 E g inimodem ATE0X3 to switch off dial tone detection Work from configuration through RS 232 can be turned on to configuration through modem by marking the modem parameter in the GSMSET program Another element ListBox for selection of the telephone number of the gate that will be configured in a remote way will appear under the field for ISDN parameters setting The background inf...

Page 23: ... the number by unwanted clicking etc the colour of the field is turned to white in case of repeated selection and it is necessary to confirm your selection again After confirmed selection of the number of the gate configured in a remote way it is possible to work with the program in the same way as in case of local configuration When clicking on the corresponding button the program will always per...

Page 24: ...ual parameters With respect to the effort to ensure compatibility with the system base as large as possible Windows 3 1 up to XP the way of editing is somehow archaic and unusual for the present age Editing in parameter fields The values can be written in a standard way upon location of the cursor in the field Deleting values can be performed only from the back using the Backspace key The complete...

Page 25: ...nnection cable A standard series cable with 9 pin connector on both ends DTE DCE modem 9 9 is used to interconnect the gate with your PC It is also marketed under the designation mouse extension cable The cable zero modem or lapling has RX and TX crossed and cannot be used directly If you wish to use this cable with an adapter the adapter has to contain crossing again If this is not the case the l...