Ideal Logic Code Combi -
Installation and Servicing
92 NO hW BUT Ch ON
93 NO DIspLay
Is there 230Vac to the boiler at L and N?
YES
NO
Supply power to the boiler
Is the wiring from the terminal block to the Main PCB
connected securely?
YES
NO
Connect the wiring from the terminal block to the
Main PCB securely.
Is the ribbon cable from the main PCB to the User
Interface PCB connected securely?
NO
Connect the ribbon from the main PCB to the User
Interface PCB securely
YES
Replace the
User Interface
PCB
L
N
Is ribbon cable damaged?
YES
Replace ribbon cable
NO
Does the display show “d” when a tap is on?
NO
Is the red neon
illuminated on the turbine
sensor?
YES
Are the flow rates correct as per Frame 2.
Is the wiring between the PCB and the diverter
valve motor connectedand is continuity OK?
YES
YES
Check diverter head fully engaged and clip
secured onto waterset.
YES
YES
Is diverter stuck in the CH position
Is the 230VAC present at the brown wire of actuator?
YES
Check and replace diverter valve motor head.
Is Boiler DHW OK?
NO
Change diverter Valve cartridge - rear section
NO
Adjust flow rates to achieve 35º
temp rise and check filter fitted in
turbine is not blocked with debris.
NO
Reconnect wiring or replace
wiring harness if no continuity.
NO
Re-engage diverter
head and secure clip to
wateset
NO
NO
Replace PCB
Replace PCB
YES
Is hot and cold
pipework crossed?
Replace PCB
NO
NO
Is the wiring connected
between PCB and DHW
sensor?
Remove the turbine, and
check for debris in the
turbine & filter. Replace
turbine if necessary. Is
DHW OK?
YES
NO
Re-connect wiring
NO
Replace turbine sensor
206279-1.indd 59
06/01/2011 09:10:50