INsTaLLaTION
Ideal Logic Code Combi -
Installation and Servicing
FLUE OUTLET
Notes.
1.
It is recommended that a support bracket
is fitted for every 1 metre of extension pipe
used and a bracket should be used at every
joint, to ensure pipes are held at the correct
angle.
If a slip joint coupling is to be used then a
bracket should be used to secure the collar.
2.
When extension ‘D’ packs are used the flue
duct MUST be inclined at 1.5 degrees to
the horizontal to allow condensate to drain
back into the boiler and out through the
condensate drain.
3.
If the B pack, or telescopic B pack only are
used, they may be mounted horizontally.
The 1.5 degrees is taken care of by the
inclination of the flue within the air pipe.
4.
Only use water as a lubricant during
assembly.
11 DETERMININg ThE FLUE LENgTh aND FLUE paCKs REqUIRED CONT’D
12 FLUE assEMBLy - Exploded View
An optional flue duct extension
kit is required for wall
thicknesses greater than :
side
378mm
Rear
420mm
telescopic b Pack shown
LEgEND
1.
Duct assembly.
2.
Flue turret.
3.
Turret clamp.
The flue terminal MUST
be fitted with the ‘TOP’
uppermost to allow the
correct fit and use of
the plume management
system.
TOP
Total Flue Length Dimension
(measuring from CL of Turret to outside wall)
Flue
Rear flue dim.
x+155
Side flue dim.
L+197
Extra packs
required
Boiler Size
Up to 640 mm
Up to 640 mm
none
26, 33 & 38
Up to 1590 mm
Up to 1590 mm
Pack D - 1 off
26, 33 & 38
Up to 2540 mm
Up to 2540 mm
Pack D - 2 off
26, 33 & 38
Up to 3490 mm
Up to 3490 mm
Pack D - 3 off
26, 33 & 38
Up to 4440 mm
Up to 4440 mm
Pack D - 4 off
26, 33 & 38
Up to 5390 mm
Up to 5390 mm
Pack D - 5 off
26, 33 & 38
Up to 6340 mm
Up to 6340 mm
Pack D - 6 off
26, 33 & 38*
Up to 7290 mm
Up to 7290 mm
Pack D - 7off
26 & 33
Up to 8240 mm
Up to 8240 mm
Pack D - 8 off
26 & 33**
Up to 9000 mm
Up to 9000 mm
Pack D - 9 off
26
Total Flue Length Dimension
(measuring from CL of Turret to outside wall)
Flue
Rear flue dim.
x+155
Side flue dim.
L+197
Extra packs
required
Boiler Size
Up to 575 mm
Up to 575 mm
none
26, 33, & 38
Up to 1525 mm
Up to 1525 mm
Pack D - 1 off
26, 33, & 38
Up to 2475 mm
Up to 2475 mm
Pack D - 2 off
26, 33, & 38
Up to 3425 mm
Up to 3425 mm
Pack D - 3 off
26, 33, & 38
Up to 4375 mm
Up to 4375 mm
Pack D - 4 off
26, 33, & 38
Up to 5325 mm
Up to 5325 mm
Pack D - 5 off
26, 33, & 38
Up to 6275 mm
Up to 6275 mm
Pack D - 6 off
26, 33, & 38*
Up to 7225 mm
Up to 7225 mm
Pack D - 7 off
26 & 33
Up to 8175 mm
Up to 8175 mm
Pack D - 8 off
26 & 33**
Up to 9000 mm
Up to 9000 mm
Pack D - 9 off
26
*Logic Code Combi 38 is capable of 6m flue only
** Logic Code Combi 33 is capable of 8m flue only
*Logic Code Combi 38 is capable of 6m flue only
** Logic Code Combi 33 is capable of 8m flue only